Combiners - Pre-Wired
MNPV6-MC4-LV
Model
|
Price
|
Size
|
Shipping
|
Weight
|
MNPV6-MC4-LV
|
$510.00
|
13.5"L x 8"W x 3.5"D
|
14"L x 9"W x 4"D
|
6 lbs
|
Model
|
MNPV6-MC4-LV
|
Price
|
$510.00
|
Size
|
13.5"L x 8"W x 3.5"D
|
Shipping
|
14"L x 9"W x 4"D
|
Weight
|
6 lbs
|
DESCRIPTION:
This 3R pre-wired MNPV6-MC4-LV combiner is rated for outdoor use.
The Pre-wired MNPV6-MC4-LV combiner with pigtails and 15A breakers is rated for outdoor use. The MNPV6-MC4-LV is rated for up to 80A 150V.
- Type 1 environmental rating
- Fast, Convenient hook up with industry standard connectors
- All aluminum powder coated housing that won't rust
- Flip up cover that can stay in the open position during installation
- PV Negative bus bar with #6 and 1/0 connections
- Chassis ground bus bar with #6 and 1/0 connections
- Included dead front cover (MNPV6DF) snaps into place after wiring is complete for safety
- Additional knockouts on bottom and sides
- Warranty - 5 yrs.
- Listed by ETL for US & Canada
- Made in the USA
California Residents: Warning
ACCESSORIES
MNBIGBABY - $71.00
General use enclosure - holds up to 4 13mm wide din rail breakers from 1-63 amps.
General use enclosure - holds up to 4 13mm wide din rail breakers from 1-63 amps.
MNEDCQUAD - $92.00
General use aluminum enclosure for 4 panel mount type breakers from 5 - 100 Amp.
General use aluminum enclosure for 4 panel mount type breakers from 5 - 100 Amp.
MNDC-GFP63 - $88.00
63 amp 150VDC din rail mount DC ground fault protector (NRTL listed breaker assy).
NEC2008 requires DC-GFP’s on all solar installations.
63 amp 150VDC din rail mount DC ground fault protector (NRTL listed breaker assy).
NEC2008 requires DC-GFP’s on all solar installations.
MNDC-GFP80 - $88.00
80 amp 150VDC panel mount DC ground fault protector (NRTL listed breaker assy) 1/2 amp trip mechanism connects between battery negative and earth ground NEC2008 requires DC-GFP’s on all solar installations.
80 amp 150VDC panel mount DC ground fault protector (NRTL listed breaker assy) 1/2 amp trip mechanism connects between battery negative and earth ground NEC2008 requires DC-GFP’s on all solar installations.
MNSPD-300-DC - $135.00
The MidNite Solar 300V Surge Protector Device (MNSPD) is a Type 1 device per UL1449 rev3 and has an outdoor rating of 4X for outdoor use. Protection for Classic and other charge controllers, off grid PV combiners and 120/240 VAC circuits.
The MidNite Solar 300V Surge Protector Device (MNSPD) is a Type 1 device per UL1449 rev3 and has an outdoor rating of 4X for outdoor use. Protection for Classic and other charge controllers, off grid PV combiners and 120/240 VAC circuits.