INVERTER SYSTEMS, Pre Wired - MidNite ROSIE
MNBCLNA-PW
Model
|
Price
|
Shipping
|
Weight
|
MNBCLNA-PW
|
$3730.00
|
40" x 16.5" x 12"
|
66 lbs. lbs
|
Model
|
MNBCLNA-PW
|
Price
|
$3730.00
|
Shipping
|
40" x 16.5" x 12"
|
Weight
|
66 lbs. lbs
|
DESCRIPTION:
The Barcelona (MNBCLNA-PW) is the most powerful and versatile systems in its class. Ideal for large size stand alone and grid-tied renewable energy systems.
PRODUCT FEATURES
- 200 amp 48V output
- 100A per MPPT output
- Includes 2 MNSPD-600 (surge protection device)
- Operating Voltage of 185 to 585 volts
- Dual independent tracking
- Ideal for larger DC coupled battery based on-grid and off-grid installations
- Talking MNGP2 display (Canbus) No other display required when coupled with MidNite inverters and other MidNite products
- Rotary knob with push button for ease of navigating menus
- Barcelona Breaker Box (MNBCLNA BB) protects against excessive battery voltage excursions
- The MNGP2 graphics and programming module allows communication, monitoring and programming of all future MidNite products from a single unit.
- Die cast aluminum enclosure
- Optional plug in AF/GF module
- Optional plug in Sunspec compliant Rapid Shutdown transmitter (module or string level)
- BTS included
- 2 Auxiliary outputs
- Quiet fan cooled. Fans relatively easy to replace
- Companion to the 7000 watt Rosie inverter
- Two PV inputs track independently
- Safety certifications: UL1741 and CE low voltage directive EN50178
- 5 year warranty
- Designed and assembled in the USA
Barcelona Pre-wired System - MNBCLNA-PW | |
Nominal Battery Voltage | 48V |
Maximum Output Current | 200 amps 2 X 100 Amps, independent |
PV Open Circuit Voltage VOC | 600VDC |
Power Conversion Efficiency | 98% (Typical system) |
Arc Fault and NEC 2020 Ground Fault Protection | Optional plugin modules - user installed |
Charging Regulation | Bulk, Absorb, Float as well as Equalization |
Battery Voltage Regulation Set Points | 40V to 65V |
Equalization Charging | Adjustable voltage and duration |
Battery Over Voltage | Fully protected. The optional Barcelona Breaker Box (MNBCLNA BB) automatically trips PV input breaker if battery exceeds 68VDC |
Battery Short Circuit | Fully protected |
Battery Temp Compensation | Automatic when BTS is installed. Adjustable mV per degree C per 2V cell |
Programmable Auxiliary | 2 auxiliary outputs |
Graphic Display | MNGP2 - 64 x 122 |
Stacking cables for system networking | Standard CAT5 - Canbus |
Communications | Canbus |
Remote Display | MNGP2 can be relocated and a second display can be added |
External Monitoring | Phone Application software allows local monitoring within normal blue tooth range from Barcelona. |
Terminal Rating | 75C |
Data Logging | 380 days of daily history |
Positive Ground Applications | Requires 2 pole input and output breakers |
Operating Temperature | Minimum of -40C to 50C (controller will auto derate as temperature rises above 25C) |
Environmental Rating | Indoor type 1 |
Warranty | 7 Years |
Weight & Dimensions | 66 lbs. |
Shipping Dimensions | 40 x 16.5 x 12 (inches) |
Certifications | Listed by ETL for US & Canada |