Breakers
MNEPV BREAKERS
POLARIZED
$22.00 ea or $240.00 12 pack
$22.00 ea or $240.00 12 pack
Model
|
Price
|
Size
|
Shipping
|
Weight
|
MNEPV BREAKERS
|
$22.00
|
Width 0.5 inches (13mm)
|
8L x 4W x 4D
|
2.5 lbs
|
Model
|
MNEPV BREAKERS
|
Price
|
$22.00
|
Size
|
Width 0.5 inches (13mm)
|
Shipping
|
8L x 4W x 4D
|
Weight
|
2.5 lbs
|
DESCRIPTION:
Sold individually for $22 each or by the case of 12 for $240
150VDC din rail mount breaker (13mm wide). Shipping dimensions are 4L x 3W x 0.5D at 0.2 Lbs
Always in stock!
150VDC din rail mount breaker (13mm wide). Shipping dimensions are 4L x 3W x 0.5D at 0.2 Lbs
Always in stock!
Note: Branch circuit rated 489A
MidNite's breakers are rated to break the full rated load at the rated voltage repeatedly, with NO DAMAGE. Always use a properly sized breaker for disconnecting.
Read about the 165 VDC ETL TEST STORY
MNEPV breakers are the same as CBI QY breakers except the standard used is inadequate for the solar industry. MidNite breakers have been evaluated by ETL to 150VDC and are listed for US and Canada. All of the NRTL listings still apply. Breakers ordered under the CBI part numbering system will not be listed for 150VDC and in many cases are not suitable for the solar industry.
All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure. Breaker Torque Value: 20 In-Lbs (2.3NM)
MidNite's breakers are rated to break the full rated load at the rated voltage repeatedly, with NO DAMAGE. Always use a properly sized breaker for disconnecting.
- POLARIZED
- Environmental Rating - Type 1 (Indoor)
- DC Voltage Rating - 150VDC
- Wire Size Range - 14 to 6 AWG
- Width - 0.5 inches (13mm)
- Number of poles - 1
- Listed for US & Canada when used in MidNite Solar enclosures
- 10,000 AIC
Read about the 165 VDC ETL TEST STORY
MNEPV breakers are the same as CBI QY breakers except the standard used is inadequate for the solar industry. MidNite breakers have been evaluated by ETL to 150VDC and are listed for US and Canada. All of the NRTL listings still apply. Breakers ordered under the CBI part numbering system will not be listed for 150VDC and in many cases are not suitable for the solar industry.
All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure. Breaker Torque Value: 20 In-Lbs (2.3NM)
California Residents: Warning
ACCESSORIES
MNDC250-X2 - $740.00
MNDC250-X2 utilizes the MidNite E-Panel enclosure. The door is blank. There are large 250A/125VDC battery breakers out each side for disconnecting two sources or loads.
MNDC250-X2 utilizes the MidNite E-Panel enclosure. The door is blank. There are large 250A/125VDC battery breakers out each side for disconnecting two sources or loads.
MNDC175-X2 - $740.00
MNDC175-X2 utilizes the MidNite E-Panel enclosure. The door is blank. There are large 175A/125VDC battery breakers out each side for disconnecting two sources or loads.
MNDC175-X2 utilizes the MidNite E-Panel enclosure. The door is blank. There are large 175A/125VDC battery breakers out each side for disconnecting two sources or loads.
MNDC250PLUS - $425.00
MNDC Plus version of the popular MNDC.
MNDC Plus version of the popular MNDC.
MNDC175PLUS - $425.00
MNDC Plus version of the popular MNDC.
MNDC Plus version of the popular MNDC.
MNDC125PLUS - $380.00
MNDC Plus version of the popular MNDC
MNDC Plus version of the popular MNDC
MNDC250 - $360.00
White powder coated aluminum chassis with 250A/125VDC breaker and 5 dinrail breaker slots or 3 panel mount breaker slots.
White powder coated aluminum chassis with 250A/125VDC breaker and 5 dinrail breaker slots or 3 panel mount breaker slots.
MNDC175 - $360.00
White powder coated aluminum chassis with 175A/125VDC breaker and 5 dinrail breaker slots or 3 panel mount breaker slots.
White powder coated aluminum chassis with 175A/125VDC breaker and 5 dinrail breaker slots or 3 panel mount breaker slots.
MNDC125 - $310.00
White powder coated aluminum with 125A/125VDC breaker and 5 dinrail breaker slots or 3 panel mount breaker slots.
White powder coated aluminum with 125A/125VDC breaker and 5 dinrail breaker slots or 3 panel mount breaker slots.
MNDC-C-SERIES - $262.00
This is a MNDC with adapter attached for the smaller panel mount breakers (3/4 inch MNEDC panel mount breaker not included).
This is a MNDC with adapter attached for the smaller panel mount breakers (3/4 inch MNEDC panel mount breaker not included).
MNBABYBOX - $59.00
General use powder coated aluminum enclosure for retrofits, small inverter disconnect, PV disconnect, AC or DC distribution.
General use powder coated aluminum enclosure for retrofits, small inverter disconnect, PV disconnect, AC or DC distribution.
MNBIGBABY - $71.00
General use enclosure - holds up to 4 13mm wide din rail breakers from 1-63 amps.
General use enclosure - holds up to 4 13mm wide din rail breakers from 1-63 amps.
MNPV3 - $154.00
Gray aluminum type 3R rainproof enclosure with deadfront, will accept three 150VDC (MNEPV) breakers or two 600 VDC fuse holders.
Gray aluminum type 3R rainproof enclosure with deadfront, will accept three 150VDC (MNEPV) breakers or two 600 VDC fuse holders.
MNPV6 - $191.00
Gray aluminum type 3R rainproof enclosure with insulating dead front, will accept six 150VDC breakers or 4 600VDC fuse holders.
Gray aluminum type 3R rainproof enclosure with insulating dead front, will accept six 150VDC breakers or 4 600VDC fuse holders.
MNPV12 - $330.00
Gray aluminum type 3R rainproof enclosure with insulating dead front, will accept 12 150VDC breakers or 10 600VDC fuse holders.
Gray aluminum type 3R rainproof enclosure with insulating dead front, will accept 12 150VDC breakers or 10 600VDC fuse holders.
MNPV6-Disco - $335.00
This 3R MNPV6 DISCO combiner is one in a series of disconnecting PV combiners from MidNite Solar. This model holds up to 6 poles of our common MNEPV and or MNEAC CBI breaker. This model will support several different configurations.
This 3R MNPV6 DISCO combiner is one in a series of disconnecting PV combiners from MidNite Solar. This model holds up to 6 poles of our common MNEPV and or MNEAC CBI breaker. This model will support several different configurations.