Small Breaker Boxes
MNBIGBABY
(Previous Model Num: BIG BABY BOX)
Model
|
Price
|
Size
|
Shipping
|
Weight
|
MNBIGBABY
|
$71.00
|
8"L x 5"W x 3"D
|
9"L x 6"W x 4"D
|
3 lbs
|
Model
|
MNBIGBABY
|
Price
|
$71.00
|
Size
|
8"L x 5"W x 3"D
|
Shipping
|
9"L x 6"W x 4"D
|
Weight
|
3 lbs
|
DESCRIPTION:
General use powder coated aluminum enclosure - holds up to 4 13mm wide din rail breakers from 1-63 amps.
The original Baby box has been a huge success in filling an industry need. We have created an enclosure called the Big Baby to over come the Baby Box smallness allowing for a ETL listed 4 position din rail box. This box is about twice as wide as the baby box giving you more wiring room. It also includes a ground box lug and mounting provisions for our short insulated bus bar as well as a ground bus bar. A dimensioned drawing is under documents on our website.
FEATURES:
- Environmental Rating - Type 1 (Indoor)
- Big Baby's DIN rail accepts up to 4 breakers (not included)
- Quad accepts up to 4 panel mount breakers (not included)
- Breakers: 1-63A
- Max. Wire - breakers 6 AWG
- Max. AC Voltage - 277VAC
- Max. DC Voltage - 300VDC
- Warranty - 5 yrs.
- Listed by ETL for US & Canada
- Made in the USA
California Residents: Warning
ACCESSORIES
MNDC-GFP63 - $88.00
63 amp 150VDC din rail mount DC ground fault protector (NRTL listed breaker assy).
NEC2008 requires DC-GFP’s on all solar installations.
63 amp 150VDC din rail mount DC ground fault protector (NRTL listed breaker assy).
NEC2008 requires DC-GFP’s on all solar installations.
MNDC-GFP50-300 - $153.00
50 amp 300VDC ground fault protector din rail mount (NRTL listed breaker assembly). 10,000 AIC
50 amp 300VDC ground fault protector din rail mount (NRTL listed breaker assembly). 10,000 AIC
MNEPV BREAKERS - $22.00
150VDC din rail mount breaker available in 1 to 63 amps (13mm wide).
150VDC din rail mount breaker available in 1 to 63 amps (13mm wide).
MNEPV 80A or 100A - $65.00
80 or 100 amp Din rail mount breaker.
80 or 100 amp Din rail mount breaker.
MNEPV-300 7A thru 50A - $46.00
7, 10, 12, 15, 20, 50 amp 300VDC din rail mount breaker. 10,000 AIC
Note: Branch circuit rated 489A
7, 10, 12, 15, 20, 50 amp 300VDC din rail mount breaker. 10,000 AIC
Note: Branch circuit rated 489A
MNSBBN - $12.00
MNSBBN - 2.3" long. Two 1/0 & four #6 wire slots. 180 amps. Comes with mounting screw& nut #10-32 x 7/8". Made in USA, NRTL recognized.
MNSBBN - 2.3" long. Two 1/0 & four #6 wire slots. 180 amps. Comes with mounting screw& nut #10-32 x 7/8". Made in USA, NRTL recognized.
MNSBB - $23.00
(Midnite Short Busbar) Shorter version of the insulated bus bars. These are useful for PV+ input on the narrow OB E-Panel and for a separate PV- bus bar for charge controllers that require them. 180 amps. Four #6 and two 1/0 wire slots.
(Midnite Short Busbar) Shorter version of the insulated bus bars. These are useful for PV+ input on the narrow OB E-Panel and for a separate PV- bus bar for charge controllers that require them. 180 amps. Four #6 and two 1/0 wire slots.