CLASSIC CHARGE CONTROLLER

124 - It is night, why does my Classic show voltage on the input?
127 - Why is ENDAMPS not triggering at my ENDAMPS setting?
133 - GRID-TIED WITH BATTERY BACKUP CAN'T GET THE CLASSIC TO SELL POWER
135 - How do I test FOLLOW-ME?
161 - Why are my Classics not sharing the work when networked with Follow-Me?
162 - Why did my Classic KWh Production RESET during the day...
169 - How does MidNite know I over-voltaged my controller?
220 - How do I perform a Software Factory Restore? (VMM =Vulcan Mind Meld) What is a VMM?
221 - How do I perform a HARDWARE factory Restore? i.e. Jumper removal
222 - Classic will not power on, no fans and no sign of start up, what do I do?
223 - Classic MNGP (display screen) is blank, but the classic is on, Why?
224 - Classic MNGP (display screen) says "RESTING" but the sun is out, Why?
225 - My classic switches from Resting and Bulk MPPT repeatedly, but is producing 0 WATTS -Why??
226 - Classic MNGP (display screen) is showing all 0's and/or GOT COMM -Why?
227 - Classic MNGP (display screen) says "MODE IS OFF" -Why?
228 - Classic MNGP (display screen) is Fuzzy or has odd characters, Why?
229 - Classic MNGP (display screen) Firmware update issues, Why will it not update?
230 - Classic MNGP (display screen) says "OCP OFF" -Why?
231 - Classic MNGP (display screen) says "OCP" -Why?
232 - Classic MNGP (display screen) says "ARC FAULT" and is Loud/Beeping - Why?
233 - Classic MNGP (display screen) says "HYPER VOC" -Why?
234 - Classic MNGP (display screen) says "Battery Over V" -why?
235 - Classic MNGP (display screen) says "SET DATE AND TIME" -Why?
236 - Classic MNGP (display screen) is White/Dark or hard to read, Why?
240 - What is the PASSWORD for the classic?
241 - Why do the FANS run all the time, no matter what the classic is doing?
242 - How can I verify that the FANS work on the Classic?
249 - Why does my Classic HYPER VOC -PV IN raise up over Voltage on its own?
256 - My Classic PV IN -IN breaker is OFF or it is night, Why does the classic show voltage?
278 - FANS seem too loud
279 - Classic goes to ABSORB at too low or too high of a voltage
280 - Classic goes to FLOAT too early
281 - Classic appears to be "singing" at a high pitch or whine that varies...
283 - I mounted my MNGP remotely and now it will NOT power up or it blinks and still will NOT power up.
291 - What is a GOT COMM message?
292 - My Classic makes a Clicking sound, Why?
293 - My Classic talks to me, makes siren sounds or comical phrases, Why?
Print
FAQ #: 161
Q: Why are my Classics not sharing the work when networked with Follow-Me?
A:Why are my Classics not sharing the work when networked with Follow-Me? When Classics are connected together using Follow-Me cables you get the following features: 1) MODE coordination. All will follow for BULK, EQUALIZATION & FLOAT. NOTE: ABSORB is NOT a Follow-me MODE, EACH Classic MUST reach the Absorb voltage setting on its own. RESTING is NOT a Follow-me MODE, each Classic goes RESTING on its own. 2) BTS aka Battery Temperature Sensor sharing. Pick a Classic to install the BTS in, it can now be called "BTS MASTER". NOTE: There is no other designation of "Master" or "Slave" with the F-Me network, All Classics can switch modes and send that data around the network. 3) Installation suggestions: A) Pick one Classic to be BTS MASTER. Set in TWEAKS to BTS NET = MASTER and all others to BTS FOLLOW. Install a BTS in this Classic ONLY. B) If using a Whizbang JR install in this Classic. NOTE: SOC% and other WBjr info is NOT shared with other Classics. C) SET BTS MASTER Classic Absorb time to what you need, set all others to 10 minutes longer. D) If using REBULK set it in the BTS MASTER Classic ONLY. The Blue LED at the top of the Classic circuit board will flash to indicate Follow-Me network operation. 1 second flash = no data, bad cable or F-Me not turned on in TWEAKS. 1/10th second blink = data okay. NOTE: You can test a F-Me cable by connecting in a Classic looping the middle jack to the bottom jack. If the cable is good and the Classic is working in F-Me the BLUE LED will go from a 1 second blink to 1/10th second. NOTE: It is common for an occasional 1-sec blink to be observed during normal operation. 4) Follow-Me is not going to make the Classics share the current they produce. Production watts & amps are going to be specific to each Classic's capabilities according to the installed input source.