Back to Documents

DOCUMENTS - RAPID-SHUTDOWN-SYSTEM-NEC-690.12

MNBIRDHOUSE1-RED
Birdhouse - Emergency Disconnect Switch. Meets 2014 NEC Rapid system shut down requirements.
MNBIRDHOUSE1-GRAY
Birdhouse - Emergency Disconnect Switch. Meets 2014 NEC Rapid system shut down requirements.
MNPV4HV-DISCO 3R-DLX
Deluxe Disconnecting Combiner has 80 amp busbars, 100 amp load break rated switch and a third pole which is the feedback micro switch.
MNPV6HV-DISCO 4X
MNPV6HV-DISCO 4X PV Disconnecting Combiner, 3 poles, 125 amp busbars, 100 amp load break rated switch.
MNPV8HV-DISCO 3R
MNPV8HV-DISCO 3R PV Disconnecting Combiner, 5 poles, 80 or 160 amp busbars depending on how they are configured. Switch is a 100 amp load break rated or 175 amps load break rated depending on configuration.
MNPV8HV-DISCO 4X
MNPV8HV Disco 4X PV Disconnecting Combiner, 5 poles, 80 or 160 amp busbars depending on how they are configured. Switch is 100 amp load break rated or 175 amps depending on configuration.
MNPV16HV-DISCO 4X
MNPV16HV DISCO 4X PV Disconnecting Combiner, 5 poles, 100 amp load break rated or 175 amps load break rated for busbars and switch.
MNPV8HV-DLTL 3R
The MNPV8HV-DLTL 3R was specifically designed for the new dual channel MPPT on transformer-less inverters.
MNPV8HV-DLTL 4X
The MNPV8HV-DLTL 4X was specifically designed for the new dual channel MPPT on the transformer-less inverters.
MNPV16HV-DLTL 4X
The MNPVHV16-DLTL-4X was specifically designed for the new dual channel MPPT on the transformer-less inverters.
MNSOB3R-2P
MNSOB3R-2P is a disconnect switch. It has a 2 channel switch that breaks both the positive and negative of a PV string to a Transformer-less inverter.
MNSOB3R-4P
MNSOB3R-4P is a Disconnect switch. It has a 4 channel switch that breaks both the positive and negative of two isolated PV strings to a Transformer-less inverter.
MNSOB4X-2P
MNSOB4X-2P is a Disconnect switch. It has a 2 channel switch that breaks both the positive and negative of a PV string to a Transformer-less inverter.
MNSOB4X-4P
MNSOB4X-4P is a Disconnect switch. It has a 4 channel switch that breaks both the positive and negative of two isolated PV strings to a Transformer-less inverter.
MNDISCOPSB
Power Supply Board for Disco Combiners in connection to the Birdhouse.
MNBDM
MNEDC125RT
125amp 125VDC Panel Mount Breaker, 1 inch wide AIC 10,000 at 125VDC
MNEDCRT 175A to 250A
175 or 250 amp breaker, 125VDC 3/8" studs 1.5" AIC 50,000 at 125VDC
MNEPV-600RT 16A thru 20A
16 or 20 Amp 600 VDC Din Rail mount breaker.
MNDC-GFP100RT-2P
100 amp 150VDC panel mount Dual DC ground fault protector (NRTL listed breaker assy)
MNCAT5-600