Product Categories

Accessories
Backup System Kits
Battery Accessories
Battery Enclosures
Breakers
Busbars
Charge Controllers for Solar, Wind, Hydro
Combiners
Combiner’s - Pre-Wired
Combiners, Disconnecting (Load Break rated)
Combiners, Disconnecting - Remote Disconnect capable (Load Break rated)
E-Panel - Apollo
E-Panel - Export
E-Panel - Magnum
E-Panel - Magnum PAE 120/240VAC
E-Panel - Outback
E-Panel - Radian
E-Panel - SMA
E-Panel - Xantrex XW, DR/TR/Samlex
E-Panel - UltraLite - Use with Nottagutter
E-Panel Lite - For use with SW, DR, RS etc.
Fuses/ Fuse Holders
Inverter Systems, Pre Wired - AC Coupled
Inverter Systems, Pre Wired - Grid Tie with Battery Backup
Inverter Systems, Pre Wired - Off Grid
Inverter Enclosures - Outdoor
Mini DC Disconnect
Nottagutter
Small Breaker boxes
Surge Protection Devices
Transfer switches
Wind and Hydro Accessories
Warranty Information | Return Merchandise Policy

Components - Breakers

NOTE:
All of Midnite Solar’s listed balance of system products qualify for the US federal tax credit when used in a new, qualifying renewable energy system.

Click on image for more info & options.
MNDC-GFP
MNDC-GFP63 Breaker
    Manual - English (Size: 466 KB)
    Download High Res Image

63 amp 150VDC din rail mount DC ground fault protector (NRTL listed breaker assy).
NEC2008 requires DC-GFP’s on all solar installations.
10,000 AIC

Breaker Torque Value: 20 In-Lbs (2.3NM)
Breaker and Busbar Torque Values

All MidNite circuit breakers hold 100% rated current independent of ambient temperature.

Listed for US & Canada

Weight: 1 Lbs
69.00
   


Click on image for more info & options.
MNDC-GFP80 Breaker
    Manual - English (Size: 466 KB)
    Specifications (Size: 255 KB)
    Download High Res Image

80 amp 150VDC panel mount DC ground fault protector (NRTL listed breaker assy) 1/2 amp trip mechanism connects between battery negative and earth ground NEC2008 requires DC-GFP’s on all solar installations.
10,000 AIC

Breaker Torque Value: 30 In-Lbs (3.4NM)
Breaker and Busbar Torque Values

All MidNite circuit breakers hold 100% rated current independent of ambient temperature.

Listed for US & Canada

Weight: 1 Lbs
69.00
   


Click on image for more info & options.
MNDC-GFP100-Dual Breaker
    Manual - English (Size: 870 KB)
    Specifications (Size: 786 KB)
    Download High Res Image

100 amp 150VDC panel mount Dual DC ground fault protector (NRTL listed breaker assy)

Breaker Torque Value: 30 In-Lbs (3.4NM)
Breaker and Busbar Torque Values

All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure.

Weight: 1 Lbs
129.00
   


Click on image for more info & options.
MNDC-GFP50-300 Breaker
    AutoCad & Visio Files (Size: 69 KB)
    Wiring Diagram (Size: 91 KB)
    Download High Res Image

50 amp 300VDC ground fault protector din rail mount (NRTL listed breaker assembly).
10,000 AIC

Breaker Torque Value: 20 In-Lbs (2.3NM)
Breaker and Busbar Torque Values

All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure.

Listed for US & Canada

Boxed: 9 x 5 x 4"
Weight: 2 Lbs
119.00
   


Click on image for more info & options.
MNEAC10
MNEAC10, MNEAC15, MNEAC20 Breaker
    Dimensional Drawing (Size: 243 KB)
    Specifications (Size: 199 KB)
    Download High Res Image

Purchase in quantity of 12 per box.

10, 15, & 20 amp 120VAC branch circuit rated 489A din rail mount.
10,000 AIC

Breaker Torque Value: 20 In-Lbs (2.3NM)
Breaker and Busbar Torque Values

All MidNite circuit breakers hold 100% rated current independent of ambient temperature.

Listed for US & Canada

Boxed: 13mm wide
Weight: 0.5 Lbs
17.00
   


Click on image for more info & options.
MNEAC30, MNEAC40, MNEAC50, MNEAC60 Breaker
    Dimensional Drawing (Size: 243 KB)
    Specifications (Size: 199 KB)
    Download High Res Image

Purchase in quantity of 12 per box.

30, 40, 50, 60 amp 120VAC Supplementary protection 1077 din rail mount.
3,000 AIC

Breaker Torque Value: 20 In-Lbs (2.3NM)
Breaker and Busbar Torque Values

All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure.

Listed for US & Canada

Boxed: 13mm wide
Weight: 0.5 Lbs
17.00
   


Click on image for more info & options.
MNEAC15-2P, MNEAC20-2P Breaker
    Dimensional Drawing (Size: 243 KB)
    Specifications (Size: 199 KB)
    Download High Res Image

Purchase in quantity of 6 per box.

15, 20 amp din rail mount 120/240 VAC Branch circuit rated 489 two pole. 10,000 AIC

Breaker Torque Value: 20 In-Lbs (2.3NM)
Breaker and Busbar Torque Values

All MidNite circuit breakers hold 100% rated current independent of ambient temperature.

Listed for US & Canada

Boxed: 26mm wide
Weight: 1 Lbs
34.00
   


Click on image for more info & options.
MNEAC30-2P, MNEAC50-2P, MNEAC60-2P Breaker
    Dimensional Drawing (Size: 243 KB)
    Specifications (Size: 199 KB)
    Download High Res Image

Purchase in quantity of 6 per box.

30, 50, 60 amp din rail mount 120/240 VAC Supplementary protection 1077 two pole.
3,000 AIC

Breaker Torque Value: 20 In-Lbs (2.3NM)
Breaker and Busbar Torque Values

All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure.

Listed for US & Canada

Boxed: 26mm wide
Weight: 1 Lbs
34.00
   


Click on image for more info & options.
MNEAC15QZD, MNEAC20QZD, MNEAC30QZD, MNEAC50QZD, MNEAC60QZD Breaker
    Dimensional Drawing (Size: 243 KB)
    Specifications (Size: 199 KB)
    Download High Res Image

Purchase in quantity of 12 per box.

White 15, 20, 30, 50, 60 amp din rail mount 277VAC Supplementary protection 1077 single pole.
3,000 AIC

Breaker Torque Value: 20 In-Lbs (2.3NM)
Breaker and Busbar Torque Values

All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure.

15 amp 30, 50, 60 Listed for US & Canada

Weight: 0.5 Lbs
17.00
   


Click on image for more info & options.
MNEAC30QZD2P, MNEAC50QZD2P, MNEAC60QZD2P Breaker
    Dimensional Drawing (Size: 243 KB)
    Specifications (Size: 199 KB)
    Download High Res Image

Purchase in quantity of 6 per box.

White 30, 50, 60 amp din rail mount 277VAC Supplementary protection 1077 double pole.
3,000 AIC

Breaker Torque Value: 20 In-Lbs (2.3NM)
Breaker and Busbar Torque Values

All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure.

Listed for US & Canada

Weight: 1 Lbs
34.00
   


Click on image for more info & options.
MNEC15QZD3P, MNEAC30QZD3P, MNEAC50QZD3P Breaker
    Download High Res Image

Purchase in quantity of 4 per box.

White or black 15, 30, 50 amp din rail mount 277VAC Supplementary protection 1077 triple pole.
3,000 AIC

Breaker Torque Value: 20 In-Lbs (2.3NM)
Breaker and Busbar Torque Values

All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure.

Listed for US & Canada

Boxed: 1.5" wide
Weight: 1.5 Lbs
54.00
   


Click on image for more info & options.
MNEDC5, MNEDC10, MNEDC15, MNEDC20, MNEDC30, MNEDC40, MNEDC50, MNEDC60, MNEDC70, MNEDC80, MNEDC90, MNEDC100 Breaker
    Specifications (Size: 64 KB)
    Download High Res Image

5, 10, 15, 20, 30, 40, 50, 60, 70, 80, 90, 100 amp 150VDC Panel Mount.
10,000 AIC

Breaker Torque Value: 30 In-Lbs (3.4NM)
Breaker and Busbar Torque Values

All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure.

Listed for AC & DC in US & Canada

Boxed: 1/2 " studs 3/4" wide
Weight: 0.5 Lbs
20.00
   


Click on image for more info & options.
MNEDC125 Breaker
    Specifications (Size: 82 KB)
    Download High Res Image

Purchase in quantity of 12 per box.

125amp 125VDC Panel Mount
AIC 10,000 at 125VDC

Breaker Torque Value: 30 In-Lbs (3.4NM)
Breaker and Busbar Torque Values

All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure.

Listed for US & Canada

Boxed: 1/4 studs 1" wide
Weight: 2 Lbs
54.00
   


Click on image for more info & options.
MNEDC175
MNEDC175 & MNEDC250 Breaker
    Specifications (Size: 125 KB)
    Download High Res Image

Purchase in quantity of 3 per box.

125VDC 3/8" studs 1.5"
AIC 50,000 at 125VDC

Breaker Torque Value: 15 Ft-Lbs (20.4NM)
Breaker and Busbar Torque Values

All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure.

Listed for US & Canada

Weight: 3 Lbs
109.00
   


Click on image for more info & options.
MNEDC60-300, MNEDC80-300 Breaker
    Specifications (Size: 547 KB)
    Download High Res Image

Purchase in quantity of 18 per box.

60 or 80 Amp 300 VDC panel mount breaker.
10,000 AIC

Breaker Torque Value: 30 In-Lbs (3.4NM)
Breaker and Busbar Torque Values

All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure.

Listed for US & Canada

Weight: 1 Lbs
40.00
   


Click on image for more info & options.
MNEPV20/50-300 Breaker
    Download High Res Image

20/50 Amp 300 VDC 4 pole din rail mount breaker.

All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure.

Breaker Torque Value: 20 In-Lbs (2.3NM)
Breaker and Busbar Torque Values

Listed for US & Canada

Weight: 1 Lbs
119.00
   


Click on image for more info & options.
MNEPV1, MNEPV2, MNEPV3, MNEPV4,
MNEPV5, MNEPV6, MNEPV7, MNEPV8, MNEPV9,
MNEPV10, MNEPV12, MNEPV15, MNEPV20, MNEPV30, MNEPV40, MNEPV50, MNEPV60, MNEPV63

    Article(Size: 109 KB)
    Dimensional Drawing (Size: 243 KB)
    Specifications (Size: 199 KB)
    Download High Res Image

Purchase in quantity of 12 per box.

150VDC din rail mount breaker (13mm wide). Always in stock!
MNEPV breakers are the same as CBI QY breakers except the standard used is inadequate for the solar industry. MidNite breakers have been evaluated by ETL to 150VDC and are listed for US and Canada. All of the NRTL listings still apply. Breakers ordered under the CBI part numbering system will not be listed for 150VDC and in many cases are not suitable for the solar industry.
150VDC ETL listed in the US and Canada
10,000 AIC

Breaker Torque Value: 20 In-Lbs (2.3NM)
Breaker and Busbar Torque Values

All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure

Listed for US & Canada

Boxed: 13mm wide
Weight: 0.5 Lbs
14.75
   


Click on image for more info & options.
MNEPV80, MNEPV100
    Article(Size: 109 KB)
    Dimensional Drawing (Size: 243 KB)
    Instructional Documentation (Size: 508 KB)
    Specifications (Size: 199 KB)
    Download High Res Image

Purchase in quantity of 10 per box.

80 or 100 amp Din rail mount breaker. MNEPV breakers are the same as CBI QY breakers except the standard used is inadequate for the solar industry. MidNite breakers have been evaluated by ETL to 150VDC and are listed for US and Canada. All of the NRTL listings still apply. Breakers ordered under the CBI part numbering system will not be listed for 150VDC and in many cases are not suitable for the solar industry.
Accepts up to #2 wire.
10,000 AIC.

Breaker Torque Value: 20 In-Lbs (2.3NM)
Breaker and Busbar Torque Values

All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure.

Listed for US & Canada

Boxed: 26mm wide
Weight: 1 Lbs
54.00
   


Click on image for more info & options.
MNEPV7-300, MNEPV10-300, MNEPV12-300 MNEPV15-300, MNEPV20-300, MNEPV30-300, MNEPV50-300 Breaker
    Download High Res Image

Purchase in quantity of 10 per box.

7, 10, 12, 15, 20, 30, 50 amp 300VDC din rail mount breaker.
10,000 AIC

MNEPV breakers are the same as CBI QY breakers except the standard used is inadequate for the solar industry. MidNite breakers have been evaluated by ETL to 300VDC and are listed for US and Canada. All of the NRTL listings still apply. Breakers ordered under the CBI part numbering system will not be listed for 300VDC and in many cases are not suitable for the solar industry.

Breaker Torque Value: 20 In-Lbs (2.3NM)
Breaker and Busbar Torque Values

All MidNite circuit breakers hold 100% rated current independent of ambient temperature.

Listed for US & Canada

Weight: 1.5 Lbs
34.00
   


Click on image for more info & options.
MNEPV16-600 and MNEPV20-600 Breaker
    Download High Res Image

16 or 20 Amp 600 VDC Din Rail mount breaker. All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure.

Breaker Torque Value: 20 In-Lbs (2.3NM)
Breaker and Busbar Torque Values

Listed for US & Canada

Weight: 2 Lbs
119.00
   


Click on image for more info & options.
MNBreaker Adapter
    Download High Res Image

1" to 3/4" Breaker Adapter
Available to distributors only in a 24 pack.

Weight: 0.5 Lbs
6.00
   


Click on image for more info & options.
MNBreaker Protecter
    Download High Res Image

The Breaker Protector will keep the 175 or 250 Amp Breaker from being accidentally hit.
Boxed: 4" x 6" x 4"
Weight: 1 Lbs
19.00