Product Categories
Accessories
Backup System Kits
Battery Accessories
Battery Enclosures
Breakers
Busbars
Charge Controllers for Solar, Wind, Hydro
Combiners
Combiner’s - Pre-Wired
Combiners, Disconnecting (Load Break rated)
Combiners, Disconnecting - Remote Disconnect capable (Load Break rated)
E-Panel - Apollo
E-Panel - Export
E-Panel - Magnum
E-Panel - Magnum PAE 120/240VAC
E-Panel - Outback
E-Panel - Radian
E-Panel - SMA
E-Panel - Xantrex XW, DR/TR/Samlex
E-Panel - UltraLite - Use with Nottagutter
E-Panel Lite - For use with SW, DR, RS etc.
Fuses/ Fuse Holders
Inverter Systems, Pre Wired - AC Coupled
Inverter Systems, Pre Wired - Grid Tie with Battery Backup
Inverter Systems, Pre Wired - Off Grid
Inverter Enclosures - Outdoor
Mini DC Disconnect
Nottagutter
Small Breaker boxes
Surge Protection Devices
Transfer switches
Wind and Hydro Accessories
|
Warranty Information
| Return Merchandise Policy
E-Panel - Magnum
NOTE:
The Magnum E-Panel comes with inverter breaker, 2/0 inverter cables, pre-wired AC input and bypass, 500amp 50mV shunt, AC terminal blocks, 100 amp DC positive and DC negative bus bars, PV input bus bar, din rails, 3 panel mount breaker knockouts, Ground bus bar, DC wiring cover, top shield, remote display mounting bracket, wall mounting brackets, charge controller bracket and lots of hardware and grommets.
ETL listed for the US and Canada.
Note: Left hand units are standard. For E-Panels built as Right hand units, an "-R" must be added to the end of the model number. Right Hand versions have the hinge on the right, circuit breakers on the right and charge control bracket on the left.
All of Midnite Solar’s listed balance of system products qualify for the US federal tax credit when used in a new, qualifying renewable energy system.

Click on image for more info & options.
Magnum
|
MNE175STM
Gray steel with 175A/125VDC inverter breaker for RD1824, RD2824, RD2624E and MS2712E
Here is a stacked pair wiring diagram: Wiring Diagram 2
Evolution of the E-Panel
Listed by ETL for US & Canada
Size: 25"L x 16"W x 4"D
Boxed: 28"L x 19"W x 11"D
Weight: 39 Lbs
|
619.00
|
|
|

Click on image for more info & options.
Magnum
|
MNE250STM
Gray steel with 250A breaker for MS4024/ MS2812/MS2012/MS4124E & RD series.
Here is a stacked pair wiring diagram: Wiring Diagram 2
Evolution of the E-Panel
Listed by ETL for US & Canada
Size: 25"L x 16"W x 4"D
Boxed: 28"L x 19"W x 11"D
Weight: 39 Lbs
|
619.00
|
|
|

Click on image for more info & options.
MNE125STMM-L
|
MNE125STMM
Designed for the Magnum Energy MM series inverters.
Listed by ETL for US & Canada
Size: 25"L x 16"W x 4"D
Boxed: 28"L x 19"W x 11"D
Weight: 22 Lbs
|
549.00
|
|
|

Click on image for more info & options.
|
MNE175ALM
White aluminum with 175a breaker for MS4024/MS2812/MS2012/MS4124E & RD series.
Evolution of the E-Panel
NOTE: Not available in right hand versions
Listed by ETL for US & Canada
Size: 25"L x 16"W x 4"D
Boxed: 28"L x 19"W x 11"D
Weight: 31 Lbs
|
659.00
|
|
|

Click on image for more info & options.
|
MNE250ALM
White aluminum with 250A breaker for MS4024/MS2812/MS2012/MS4124E & RD series.
Evolution of the E-Panel
NOTE: Not available in right hand versions
Listed by ETL for US & Canada
Size: 25"L x 16"W x 4"D
Boxed: 28"L x 19"W x 11"D
Weight: 31 Lbs
|
659.00
|
|
|

Click on image for more info & options.
|
MNErightdoorSTM
Gray steel right hand hinge door with LH charge control mounting bracket for wide chassis.
Size: 25"L x 16"W x 1/2"D
Boxed: 30"L x 17"W x 1"D
Weight: 8 Lbs
|
75.00
|
|
|
|
|
|
|