Product Categories

Accessories
Backup System Kits
Battery Accessories
Battery Enclosures
Breakers
Busbars
Charge Controllers - Brat
Charge Controllers - Classics
Charge Controllers - KID
Combiners
Combiners - AC Micro Inverter (Example - Enphase)
Combiners - Disconnecting
Combiners - Pre-Wired
E-Panel - Magnum PAE 120/240VAC
E-Panel - Magnum
E-Panel - Outback
E-Panel - Samlex
E-Panel - Schneider Conext SW
E-Panel - Schneider Electric XW
E-Panel - SMA
E-Panel - UltraLite - Use with Nottagutter
E-Panel Lite - For use with TraceSW, DR, RS etc.
Fuses/ Fuse Holders
Inverter Systems, Pre Wired - AC Coupled
Inverter Systems, Pre Wired - Grid Tie with Battery Backup
Inverter Systems, Pre Wired - Off Grid
Inverter Systems, Pre Wired - UPS (Backup Power)
Mini DC Disconnect
Nottagutter
RAPID-SHUTDOWN-SYSTEM-NEC-690.12
Small Breaker Boxes
Software
Surge Protection Devices
Transfer switches
Wind and Hydro

RAPID-SHUTDOWN-SYSTEM-NEC-690.12

Back to RAPID-SHUTDOWN-SYSTEM-NEC-690.12
Printer Friendly Version
Download High Resolution Image
MNLSOB-R1-1000
1000V SOB (Shut Off Box) Receiver for Strings
Model
Price Shipping Weight
MNLSOB-R1-1000
$154.00 7.625"L x 7.38"W x 3.5"D 1 Lbs
The MidNite SOB (Shut Off Box) is a simple to install, low cost rapid shut down system designed to comply with 2014 as well as 2017 NEC.

The system uses a receiver at the module that wires in just like an optimizer and a transmitter that is installed in or near the Inverter. The installer does not need to install any other wiring between the transmitter and receiver. The system is fail safe, if the receiver does not sense the keep alive data stream from the transmitter, it turns off and opens the circuit.

  • Receiver is fail safe, if PLC signal goes away the SOB turns off the string
  • A receiver is placed at the end of each string. Up to six strings
  • Module level shut down can be achieved by installing one receiver per panel
  • 1000 string voltage
  • 80V maximum panel voltage
  • 12A maximum string current
  • Operating temperature range: 1000V – 40ºC to +80ºC
  • Tested to 4000 feet round trip of pv wiring
This is a new product and supplies will be limited until production is 100%.
The MNLSOB system was designed to work with grid-tied Inverters. At this time, it does not work with charge controllers.

California Residents: Warning

Description: The MidNite SOB (Shut Off Box) is a simple to install, low cost rapid shut down system designed to comply with 2014 as well as 2017 NEC.

Product Search