Product Categories

Accessories
Backup System Kits
Battery Accessories
Battery Enclosures
Breakers
Busbars
Charge Controllers - Brat
Charge Controllers - Classics
Charge Controllers - KID
Combiners
Combiners - AC Micro Inverter (Example - Enphase)
Combiners - Disconnecting
Combiners - Pre-Wired
E-Panel - Magnum PAE 120/240VAC
E-Panel - Magnum
E-Panel - Outback
E-Panel - Samlex
E-Panel - Schneider Conext SW
E-Panel - Schneider Electric XW
E-Panel - SMA
E-Panel - UltraLite - Use with Nottagutter
E-Panel Lite - For use with TraceSW, DR, RS etc.
Fuses/ Fuse Holders
Inverter Systems, Pre Wired - AC Coupled
Inverter Systems, Pre Wired - Grid Tie with Battery Backup
Inverter Systems, Pre Wired - Off Grid
Inverter Systems, Pre Wired - UPS (Backup Power)
Mini DC Disconnect
Nottagutter
RAPID-SHUTDOWN-SYSTEM-NEC-690.12
Small Breaker Boxes
Software
Surge Protection Devices
Transfer switches
Wind and Hydro Accessories
Wind Products

Busbars

Back to Busbars
Printer Friendly Version
Download High Resolution Image
NOTTAGUTTER
Model
Price Size Shipping Weight
NOTTAGUTTER
$699.00 37.5"L x 14"W x 3.5"D 40"L x 16"W x 6"D 20 Lbs
Competing systems mount the inverters too close together. Notice the physical separation between inverters on the Nottagutter that offers better cooling and improved reliability. Higher charger rates are also achieved due to improved cooling. The Nottagutter also takes up less wall space.

The ends are designed to accept inverters, charge controllers or inverter battery breakers. Features include massive DC+ and DC- busbars to accommodate up to four inverters and auxiliary DC circuits. Terminal busbars include 120/240V AC input, AC output, Neutral and ground busbars. Additional space allows for three phase busbars. 60 amp AC Bypass is standard.

FEATURES:
  • Environmental Rating - Type 1 (Indoor)
  • Install up to four E-Panels with each Nottagutter.
  • The Nottagutter accepts two E-Panels on top and two E-Panels bottom or on the sides
  • Includes one 2 pole 60 amp bypass breaker and two 2 pole 60 amp inverter breakers
  • Accommodates up to 4 120v inverters like the Outback FX or 2 of the 240v inverters like the Magnum PAE series as shipped and can be expanded to 8 120v inverters or 4 240v inverters
  • Plus and minus busbars
  • Optional Din Rail bracket to support 6 additional Din Rail breakers
  • Locations for 2 panel mount breakers from 5 amp to 250 amp. See accessories below
  • Main Breaker Current Rating - 250A
  • Number of spaces - 12
  • Bus bar rating - 180A
  • Environment type - 1 (Indoor)
  • Max. Wire Size - 4/0
  • Max. AC Voltage - 277VAC
  • Max. DC Voltage - 300VDC
  • Warranty - 5 yrs.
  • Listed by ETL for US & Canada
  • Made in the USA
Description:

Recommended Accessories


MNSPD-115 - $119.00
The MidNite Solar 115V Surge Protector Device (MNSPD) is a Type 2 device per UL1449 rev3 and has an outdoor rating of 4X for outdoor use. Protection for battery circuits.


MNSPD-300-DC - $119.00
The MidNite Solar 300V Surge Protector Device (MNSPD) is a Type 2 device per UL1449 rev3 and has an outdoor rating of 4X for outdoor use. Protection for Classic and other charge controllers, off grid PV combiners and 120/240 VAC circuits.


MNSPD-600 - $119.00
The MidNite Solar 600V Surge Protector Device (MNSPD) is a Type 2 device per UL1449 rev3 and has an outdoor rating of 4X for outdoor use. Protection for grid-tie PV combiners and inverter input circuits.


MNE175STMULite - $549.00
175 A/120 VAC wide Magnum steel Left hand UltraLite E-Panel.


MNE250STMULite - $549.00
250 A/120 VAC wide Magnum steel Left hand UltraLite E-Panel.


MNE175STM-240ULite - $649.00
175 A/120/240 VAC wide Magnum steel Left hand UltraLite E-Panel.


MNE250STM-240ULite - $649.00
250 A/120/240 VAC wide Magnum steel Left hand UltraLite E-Panel.


MNEDC 5A thru 100A
5, 10, 15, 20, 30, 40, 50, 60, 70, 80, 90, 100 amp 150VDC Panel Mount. 10,000 AIC


MNEPV 1A thru 63A
150VDC din rail mount breaker available in 1 to 63 amps (13mm wide).


MNEPV 80A or 100A
80 or 100 amp Din rail mount breaker.


MNEDC 175A or 250A
175 or 250 amp breaker, 125VDC 3/8" studs 1.5" AIC 50,000 at 125VDC


MNEPV-300 7A thru 50A
7, 10, 12, 15, 20, 30, 50 amp 300VDC din rail mount breaker. 10,000 AIC
Note: Branch circuit rated 489A


MNEDC125RT - $54.00
125amp 125VDC Panel Mount Breaker, 1 inch wide AIC 10,000 at 125VDC


MNEAC 5A thru 25A - $17.00
5, 10, 15, & 20 amp 120VAC branch circuit rated 489A din rail mount. 10,000 AIC


MNEAC 30A thru 60A
30, 40, 50, 60 amp 120VAC Supplementary protection 1077 din rail mount. 3,000 AIC


MNEAC-2P 15A thru 25A
15, 20 & 25 amp din rail mount 120/240 VAC Branch circuit rated 489 two pole. 10,000 AIC


MNEAC-2P 30A thru 60A
30, 50, 60 amp din rail mount 120/240 VAC Supplementary protection 1077 two pole. 3,000 AIC


MNEACQZD 10A thru 60A
White 15, 20, 30, 50, 60 amp din rail mount 277VAC Supplementary protection 1077 single pole. 3,000 AIC


MNEACQZD-2P 20A thru 60A
White 30, 50, 60 amp din rail mount 277VAC Supplementary protection 1077 double pole. 3,000 AIC


MNEACQZD-3P 15A thru 60A
White 15, 30, 50 amp din rail mount 277VAC Supplementary protection 1077 triple pole. 3,000 AIC


MNBREAKER PROTECTOR - $19.00
The Breaker Protector will keep the 175 or 250 Amp Breaker from being accidentally hit.


MNBREAKER ADAPTER - $6.00
1" to 3/4" Breaker Adapter.


MNNOTTAGUTTER-DR - $30.00
Din rail to fit the Nottagutter, includes mounting hardware.

Product Search